phenix.mtriage - Cryo-EM Map Analysis
================================================================================

Input file: map.mrc

------------------------------------------------------------------------------
Map Statistics
------------------------------------------------------------------------------

Map dimensions: 256 x 256 x 256
Voxel size: 1.05 A
Map origin: 0.0, 0.0, 0.0

------------------------------------------------------------------------------
Resolution Estimation
------------------------------------------------------------------------------

d_FSC (0.143 cutoff): 3.2 A
d_FSC (0.5 cutoff): 3.8 A
d99: 3.1 A

Estimated resolution: 3.2 A

------------------------------------------------------------------------------
Map Quality Metrics
------------------------------------------------------------------------------

Map-model CC (if model provided): N/A
Local resolution range: 2.8 - 4.5 A
Mean local resolution: 3.3 A

Map sharpening B-factor: -85.2 A^2

------------------------------------------------------------------------------
Recommended Actions
------------------------------------------------------------------------------

- Resolution is suitable for model building
- Consider local resolution filtering for refinement
- Map quality appears good for automated building

================================================================================
phenix.mtriage completed successfully
================================================================================